# Ambient Noise Monitoring | Validate Test Conditions | Auditdata Measure

> See your testing environment as you work. The new ambient noise microphone gives clinicians real-time visibility into test conditions — particularly valuable for domiciliary care.

# **Ambient Noise Monitoring**, Wherever You Test

Measure now lets you monitor room noise as you test, so you always know what's in the environment. Ideal for out-of-booth testing, home visits, and any space where conditions vary.

## Reasons to **Add Ambient Noise Monitoring**

<span style="   display: inline-flex;   align-items: center;   justify-content: center;   width: 32px;   height: 32px;   border-radius: 50%;   background: #89C3D0;   color: #fff;   font-family: 'Siri', sans-serif;   font-weight: 600;   font-size: 14px; ">01</span>

## Take Your Business on the Road

Out-of-booth testing and mobile audiometry is growing. Ambient noise monitoring lets your clinicians demonstrate they found a sufficiently quiet test environment, whether they're on a house call, in a satellite clinic, or running mobile audiometry.

<span style="   display: inline-flex;   align-items: center;   justify-content: center;   width: 32px;   height: 32px;   border-radius: 50%;   background: #89C3D0;   color: #fff; ">   <i class="fa-sharp fa-solid fa-arrow-right" style="font-size: 14px;"></i> </span>

## The Result

A record of the test conditions. Your clinician gets confidence in the result.

<span style="   display: inline-flex;   align-items: center;   justify-content: center;   width: 32px;   height: 32px;   border-radius: 50%;   background: #FDD3A9;   color: #1D3F43;   font-family: 'Siri', sans-serif;   font-weight: 600;   font-size: 14px; ">02</span>

## Catch Environment Problems

Environmental noise directly impacts test results. Ambient noise monitoring displays the noise floor against your chosen MPANL in real time, so you can trust your results before they influence a fitting decision.

<span style="   display: inline-flex;   align-items: center;   justify-content: center;   width: 32px;   height: 32px;   border-radius: 50%;   background: #FDD3A9;   color: #1D3F43; ">   <i class="fa-sharp fa-solid fa-arrow-right" style="font-size: 14px;"></i> </span>

## The Result

Clinical confidence in your testing environment. Cleaner records.

<span style="   display: inline-flex;   align-items: center;   justify-content: center;   width: 32px;   height: 32px;   border-radius: 50%;   background: #F48037;   color: #fff;   font-family: 'Siri', sans-serif;   font-weight: 600;   font-size: 14px; ">03</span>

## Honest Tooling for Honest Clinical Work

This is real-time ambient noise monitoring to help clinical awareness of their testing environment and not a substitute for ISO type 1 or type 2 sound level meters.

<span style="   display: inline-flex;   align-items: center;   justify-content: center;   width: 32px;   height: 32px;   border-radius: 50%;   background: #F48037;   color: #fff; ">   <i class="fa-sharp fa-solid fa-arrow-right" style="font-size: 14px;"></i> </span>

## The Result

If you need ISO-compliant measurement, you need a dedicated meter. If you need real-time awareness while you test, this is the tool.

## **What the Ambient Mic Does** and What It's Not Intended for

![Ambient Noise - Auditdata Measure](https://www.auditdata.com/media/kgnfu2je/screenshot-2026-05-27-084036.png)

<span style="   display: inline-flex;   align-items: center;   justify-content: center;   width: 32px;   height: 32px;   border-radius: 50%;   background: #89C3D0;   color: #fff;   font-size: 14px; ">   <i class="fa-sharp fa-regular fa-check"></i> </span>

## Real-Time Visibility

Shows ambient noise levels in the test space in real time, so clinicians can adjust conditions or confirm the environment is right before testing.

<span style="   display: inline-flex;   align-items: center;   justify-content: center;   width: 32px;   height: 32px;   border-radius: 50%;   background: #89C3D0;   color: #fff;   font-size: 14px; ">   <i class="fa-sharp fa-regular fa-check"></i> </span>

## Performance Matched to REM Mic

The microphone is calibrated to the same standard as the Measure REM probe microphone, with consistent measurement performance.

<span style="   display: inline-flex;   align-items: center;   justify-content: center;   width: 32px;   height: 32px;   border-radius: 50%;   background: #89C3D0;   color: #fff;   font-size: 14px; ">   <i class="fa-sharp fa-regular fa-check"></i> </span>

## Built for Out-of-Booth Testing

Designed for clinicians working in patient homes, satellite sites, or any setting where the testing environment varies.

<span style="   display: inline-flex;   align-items: center;   justify-content: center;   width: 32px;   height: 32px;   border-radius: 50%;   background: #89C3D0;   color: #fff;   font-size: 14px; ">   <i class="fa-sharp fa-regular fa-check"></i> </span>

## Instant Alerts When It Matters

With assistant warnings enabled, clinicians see instant alerts when ambient noise exceeds permitted maximum levels, so they can take action in the moment.

<span style="   display: inline-flex;   align-items: center;   justify-content: center;   width: 32px;   height: 32px;   border-radius: 50%;   background: #1D3F43;   color: #89C3D0; ">   <i class="fa-sharp fa-solid fa-xmark" style="font-size: 16px;"></i> </span>

## ISO Sound Level Metering

The ambient noise microphone does not meet ISO type 1 or type 2 sound level meter standards. If your protocols require ISO-compliant measurement, use a dedicated sound level meter alongside Measure.

<span style="   display: inline-flex;   align-items: center;   justify-content: center;   width: 32px;   height: 32px;   border-radius: 50%;   background: #1D3F43;   color: #89C3D0; ">   <i class="fa-sharp fa-solid fa-xmark" style="font-size: 16px;"></i> </span>

## Audiometric Room Certification

Use a calibrated sound level meter and your local certifying body's protocols for room-level audiometric certification.

## **Bring Diagnostic-Quality Testing** to Any Setting

## **Elevate Audiometry** with Measure

![Free Field Test Auditdata Measure](https://www.auditdata.com/media/mmih3c5h/free-field-test-auditdata-measure.png)

→ [Pure-Tone Audiometry](https://www.auditdata.com/audiology-solutions/measure/hearing-assessment/pure-tone-audiometry/ "Pure-Tone Audiometry")

→ [Measure Software overview](https://www.auditdata.com/audiology-solutions/measure/software/ "Software")

→ [Services — calibration & CalTool 240](https://www.auditdata.com/audiology-solutions/measure/software/ "Software")